Shore power #1, Marinco GalvanAlert

Ben Ellison

Ben Ellison

Panbo editor, publisher & chief bottlewasher from 4/2005 until 8/2018, and now pleased to have Ben Stein as a very able publisher, webmaster, and editing colleague. Please don't regard him as an "expert"; he's getting quite old and thinks that "fadiddling fumble-putz" is a more accurate description.

10 Responses

  1. Terry says:

    The wiring for power distribution in North America is so…rats nest. We’re in so deep I don’t know if it’s something that can be corrected.
    Maybe the cause for the pole reversal is somewhere in the system there is a difference in potential building up then discharging like a cap.

  2. Andre says:

    This seems like a great device.. But my question is, what if (after spending $140 bucks), you plug this thing in, and it indicates you have galvanic corrosion occuring at your marina.
    Then what? How do you track that down? (without calling an electrician and spending several hundred if not thousands of dollars). Is there a procedure a layman can follow for that?

  3. Paul L says:

    On the reverse polarity issue, see the write up on the Bluesea’s site
    http://bluesea.com/viewresource/85
    Paul L

  4. Ben Ellison Ben Ellison says:

    That’s interesting, Paul, but in the situation I’m describing the reverse polarity LEDs were not “faintly illuminated.”
    I don’t have a good answer for you, Andre, but first off I might unplug my shore power, especially if I saw the “High Activity” warning. Hopefully, other commenters will have more advice.

  5. DaveV says:

    Ben-
    Shore power is derived from a 240V “Y” system. Each 120V AC output is derived from two legs of the “Y” and there are 3 circuits available. There is a common return or ground among all three to handle an imbalance in the loads across the three legs. If there is a huge imbalance between the legs it may cause what appears to be a reversal of polarity as that leg appears to change its relationship to the common ground. The changes that are occuring represent the variation in loads being applied and removed across the two legs you are NOT connected to. Sounds like there has been a poor arrangement of the load distribution across the 3 legs of the supply system.
    The one circuit you are locating that appears to work is either from another Y or is “lucky” with respect to the loads that are on the other legs. There may be other complications – such as inductive loads (motors) causing poor “load factors” on the lines that appear to have the polarity reversal.
    WRT what to do if you do find out that there are major galvanic currents at play is to go out and buy and install (properly) an ISOLATION TRANSFORMER – with no DC ground return from the BOAT (output) side of the transformer direct back to the dock. All connections to your boat will then be via induction in the transformer and will stop DC based corrosion. (AC current does not corrode but it can KILL – http://boatingsailing.suite101.com/article.cfm/electric_shock_drowning )
    Also check the BlueSea info on Ground Faults –
    http://bluesea.com/files/resources/technical_briefs/Technical_Brief_AC_Ground_Faults.pdf

  6. Ben Ellison Ben Ellison says:

    Thanks, Dave! I forgot about isolation transformers, and I’d even tried to explain their value once:
    http://www.powerandmotoryacht.com/boat-electronics/boat-isolation-transformers/

  7. SeaBlazer says:

    An isolation boost transformer is your best friend when it comes connecting to shore power. I have a large vessel and where I’m located getting 220V on the dock is a problem. With an isolation boost transformer I can power my 220V panel from a 110V shore power connection. (Keep in mind the current is cut in half). I have a 15KVA transformer made in Canada. Works great. My boat is moored in brackish, mostly fresh water area, on a dock with a lot of steel commercial vessels. The marina is “hot” and everybody seems to know that, zincs tend to disappear rapidly; the isolation transformer fixed the problem. In a salt water marina, an electrical leak to ground tends to short out quickly and trip the breaker, in fresh water there is enough resistance to keep this from happening. I’ve heard that more swimmers are injured and killed in fresh water than salt water because of this.

  8. Waterpilot says:

    Have you done review of the Sinergex Fusion charger, Kinda losing the battle with the Xantrex Prosine 2.0 (float problem) and looking for solution to support the 2 Lifeline 4 Ds I just got recently. Can you help. Annapolis

  9. Mitch says:

    Where can one of these be bought? I’ve tried several sites? Why can’t I find one to be bought? It seems like a great device?

  10. Ben Ellison Ben Ellison says:

    Mitch, I don’t know what happened to this product, but Hubbell has a somewhat similar tester:
    https://southernboating.com/electronics-and-gear/electronics/hubbell-marines-twist-lock-circuit-tester/